PRODUCTS
ELECTRICAL PROBE SYSTEMS
THERMAL PLATES
LIQUID CRYSTAL SYSTEMS
RESOURCES
SUPPORT
ABOUT
For optical microscopy and spectroscopy
-190°C - 400°C with liquid nitrogen cooling option
Large 38 mm × 50 mm sample area ideal for standard 25mm x 75mm glass slides
Integrated XY sample positioning
Sealed chamber with gas purging capability [0.5 Bar positive pressure]
Rough-vacuum compatibility [1mBar]
The HCS302GXY features a gas tight sample chamber which can be purged to prevent condensation or to make measurements under a controlled atmosphere. The silver thermal block is controllable from -190°C to 400° with a temperature stability of ±0.05°C. The 50mm x 50mm sample area is ideal for 25mm x 75mm glass slides which can be externally positioned using the integrated XY micromanipulators. Top and bottom dual pane windows are removable and exchangeable to meet a range of spectroscopic needs. An optional inner thermal cover is also included for work requiring ultra-high temperature stability and uniformity (reduces sample area to 45mm to 50mm).
Upgrade to the HCS302GXY+ customizable model to enable customizations such as transmission aperture adjustment, vertical mounting capabilities, electrical feedthroughs, custom sample holders and much more!
The HCS302GXY is a versatile and budget-friendly option for experiments requiring atmospheric control.
Temperature Control |
mK2000 with programmable precision switching PID output |
Sample Thermal Cover |
Removable Inner sample cover with additional window |
Minimum Temperature |
-190°C (with optional liquid N2 cooling) |
Maximum Temperature |
400°C |
Temperature Sensor |
100 Ω Platinum RTD |
Maximum Heating Rate |
+100°C per minute at 100°C |
Maximum Cooling Rate |
-50°C per minute at 100°C |
Minimum Heating and Cooling Rate |
±0.01°C per minute |
Temperature Resolution |
0.01°C |
Temperature Stability |
±0.05°C (>25°C), ±0.1°C (<25°C) |
Power supply |
Universal power input - 300W max |
Software |
Windows software to record and export temperature-time data |
Optical access |
Reflection and transmission capability |
Optical windows |
Removable and exchangeable quartz glass windows permit full-spectrum transparency. Other options such as IR compatible or Kapton windows are available by request |
Minimum Objective Working Distance |
6.6 mm |
Minimum Condenser Working Distance |
14.7 mm |
Top Window Aperture |
27 mm diameter aperture with 31.75mm Quartz glass window |
Top Viewing Angle |
±55.0° from normal |
Bottom Window Aperture | 16 mm diameter aperture with 20mm Quartz glass window |
Bottom Viewing Angle |
±17.5° from normal |
Transmission Aperture |
2 mm diameter (4mm option available with customization) |
Window Defrost |
External top window defrost, Integrated bottom window defrost |
Sample Area |
50 mm x 50 mm (45mm x 50mm with inner lid) |
Chamber Height |
4.3 mm without removeable inner cover 2.1 mm with removeable inner cover |
Sample Positioning |
10 mm fine travel with Vernier XY dials for remote manipulation in sealed chamber |
Atmosphere Control |
Supports positive pressure gas purge up to 0.5 Bar to control humidity, condensation, and oxidation Supports rough vacuum down to 1mBar |
Frame Cooling |
Integrated frame cooling with optional chiller system |
Mounting |
Base model includes tapped holes on frame and removable side-mounted L-Brackets. Horizontal mounting adaptors available for select instruments, or by custom design |
Frame Dimensions |
177 mm x 90 mm x 25 mm |
Weight |
1090 g |
HCS302GXY Base-Model Options
Add-on options for the HCS302GXY base model are listed below. These items can be added at any time, and can even be installed by the end-user in the field. When adding a cooling system to an existing HCS302GXY system, it may be necessary to upload a new parameter file to the temperature controller.
Active Sample Cooling The standard HCS302GXY supports precision temperature control from room temperature to 400°C. Enable active sample cooling with one of our LN2 suction-pump cooling systems to enable active cooling rates as high as -50°C/min and a lower temperature limit of -190°C. Note: When cooling below -60ºC, it is highly recommended to utilize the gas tight stage body to prevent condensation and ice formation | |
- Add LN2-P4D3 Cooling System 4-stage LN2 suction pump cooling system with 3L LN2 Dewar PN: LN2-P4D3 |
- Add LN2-P8D10 Cooling System 8-stage LN2 suction pump cooling system with high-capacity 10L LN2 Dewar PN: LN2-P8D3 |
Window Material
The HCS302GXY utilizes removable and exchangeable windows to optimize performance for any wavelength. Base-model options are shown below, but specialized options are available per request with the HCS302GXY+ model. Note: The exact window part number depends on desired chamber lid, as multiple sizes are available | |
- Quartz Glass (Standard) PN: WQ1 |
- BaF2 Glass for IR PN: WBaF2 |
- ZnSe Glass for IR PN: WZnSe |
- CaF2 Glass for IR PN: WCaF2 |
- Saphire Glass for UV/IR PN: WSP |
|
Sample Mounting The HCS302GXY is typically used in a horizontal configuration with the integrated XY positioners and uses gravity to secure the sample against the thermal block. While the HCS302GXY is typically used with standard 25mm x 75mm glass slides, non-standard mounting solutions can be designed to accomodate sizes that are larger or smaller than a 25mm x 75mm glass slide. Threaded holes on the sample area are included with each HCS302GXY base model, and can be used to mount a custom sample clamp to secure the sample in place, bypassing the XY mechanism. Alternativley, custom XY sample tounges can be designed to accomodate non-standard samples, while remaining compatible with the integrated XY positioners. For more information, contact sales@instec.com and provide information on your ideal samples. | |
- Threaded holes on thermal block (Standard) 50mm x 50mm square hole pattern PN: HCS302GXY |
- Custom sample holders Sample clamps and XY positioner tounges PN: HCS302GXY-MTcustom+ |
Environmental Control Replicate test conditions using the HCS302GXY's gas tight chamber and our RHC01 humidity controller. | |
- Very rough Vacuum [1 mBar] / +0.5 Bar gas-purge (Standard) PN: HCS302GXY |
- Add Humidity Control with RHC01 PN: RHC01 |
Mounting Adapters Mounting adaptors allow the HCS302GXY to be easily mounted onto your optical instrument of choice. All HCS302GXY models include side-mounted L-brackets and tapped holes on the base for easy mounting to any instrument. Optional mounting adaptors are available for Instec's TPM-CX40, Olympus, Leica, and many more microscope models. For the full list of mounting adaptors, contact sales@instec.com. | |
- None (Standard) |
- Horizontal |
- Vertical (available with customization) |
Special options for HCS302GXY+ customizable model
Upgrade to HCS302GXY+ for access to special options including:
Transmission Aperture Some applications require larger transmission apertures than others- whether it be to see more of a sample, allow for more light transmission, or for compatibility with specialized instruments. However, larger transmission apertures also result in larger thermal gradients across the observation area, decreasing the temperature uniformity. Tune the HCS302GXY+ transmission aperture size to optimize the temperature uniformity while maximizing the transmission aperture size. | |
- 2mm aperture (Standard) |
- 4mm aperture PN: AP4-HCS302GXY |
Electrical Feedthroughs For applications that require optical access with simultaneous temperature control and electrical testing, a range of gas tight electrical feedthroughs may be added to the HCS302GXY+ customizable model. The HCS302GXY+ supports up to 2 additional standalone electrical feedthroughs, which may consist of a combination of up to 2 of any electrical feedthrough types. BNC type feedthroughs are available in two configurations: Grounded, where the outer BNC conductor is connected to earth ground for shielding, and Floating, where the outer BNC conductor is left floating relative to earth ground allowing the shielding conductor to be used as a second signal conductor. The Floating BNC configuration includes a second pogo-pin terminal for each feedthrough. | |
- No electrical feedthroguhs (Standard) PN: HCS302GXY |
- 1x or 2x Grounded BNC Connectors with pogo pin terminals PN: F1V-HCS302GXY |
- 1x or 2x Floating BNC Connectors with 2x pogo pin terminals each PN: F2V-HCS302GXY |
- 1x or 2x machinable gastight blanks for DIY feedhtroughs PN: F0V-HCS302GXY |
- Customized standalone electrical feedthrough (DB-9, ribbon-cable, fiber optic, RF and much more!) | |
Upgraded Temperature Controller Options
The HCS302GXY is designed for use with Instec's mK2000 series temperature controllers. While the switching PID controller is recommended for most applications, in cases where low electrical noise is critical, the temperature controller may be upgraded to an LVDC output model. Furthermore, the mK2000 itself can be customized with various add-on options such as additional monitoring sensors, analog voltage output and more.... | |
- mK2000B with switching PID output (Standard) PN: mK2000B |
- mK2000B with LVDC output upgrade PN: mK2000B-LVDC |
- Additional monitoring sensor for mK2000B PN: mK2000B-TMK |
- Advanced controller upgrades (see mK2000B page for details) Ask sales@instec.com for more details |
Custom Options
If you can imagine it, Instec can make it! Instec offers complete customization services to tailor any of our standard products to your unique application. | |
- KBr, Kapton windows with custom lid |
- Custom covers |
- SMA feedthroughs |
- Floating surface area with Triaxial BNC |
- Custom sample holder |
... And much more! |
Contact sales@instec.com for more information