PRODUCTS
ELECTRICAL PROBE SYSTEMS
THERMAL PLATES
LIQUID CRYSTAL SYSTEMS
RESOURCES
SUPPORT
ABOUT





Modular electrical probing stage
-190°C to 600°C with 26mm hexagonal sample area
Gastight chamber with optical access
4 or 6 electrical probers
Upgradable to fine XYZ micropositioning
The HCP621G-MP (V10.02.00) is a gastight, temperature-controlled modular probing stage capable of heating and cooling between -190°C and 600°C. Four (4) or Six (6) independent, electrical probers are manually positioned onto the sample, which rests on a 26mm hexagonal thermal block (Silver). The standard electrical probers are reccomended for electrical pads larger than 600um x 600um, while the upgraded -MPeX sliding probers are reccomended for smaller pads (250um x 250um minimum), or for samples that are sensitive to thermal expansion. Electrical heating provides precision temperature control up to 600°C, while Instec's optional LN2-P system enables sample cooling via LN2 circulation down to -190°C.
The HCP621G-MP gastight chamber supports a positive-pressure gas purge up to +0.5 Bar for reactive/ Inert gasses or humidity control. The alternative HCP421V-MP supports rough 10*10^-3 mBar evacuation for prevention of condensation or oxidation while heating/ cooling. The vacuum-tight version is strongly recommended for extended duration experiments at low temperatures, but has a reduced upper heating limit of 400ºC under vacuum.
This modular probing stage is ideal for performing electrical device or materials characterization, and can easily be used with optical instruments to add temperature control capabilities to almost any optical tool. This probing stage can also easily be upgraded to enable fine XYZ movement via micrometer dials on the prober frame, ultimately allowing prober movement even when the chamber is sealed and uunder vacuum.
Upgrade to the HCP621G-MP+ model to access advanced customization options such as additional electrical feedthroughs, transmission apertures, triaxial/ SMA connector options, custom lids and much more.
For more information on INSTEC probing solutions, check out our full Electrical Probing Solutions Catalog!
Note: All images and specifications are for reference only, and are subject to change at any time without notice. Always confirm final technical specifications with our sales team before placing an official order.
Upgrade to the HCP621G-MPH non-paramagnetic probing chamber to perform Hall Effect studies with simultaneous precision temperature control and atmospheric control.
Temperature Control |
mK2000B with programmable precision LVDC output to minimize electrical noise |
Thermal Block |
Silver thermal block for superior thermal uniformity |
Minimum Temperature |
-190°C (with optional liquid N2 cooling) |
Maximum Temperature |
600°C |
Temperature Sensor |
100 Ω Platinum RTD |
Maximum Heating Rate |
+50°C per minute at 100°C * Faster rates avialable by request |
Maximum Cooling Rate |
-50°C per minute at 100°C * Faster rates avialable by request |
Minimum Heating and Cooling Rate |
±0.01°C per minute |
Temperature Resolution |
0.01°C |
Temperature Stability |
±0.05°C (>25°C),±0.1°C (<25°C) |
Power Supply |
Universal power input - 150W max (not including LN2 system or water cooling accessory) |
Software |
Windows 10/11 software to record and export temperature-time data |
Electrical Probes |
Four (4) or Six (6) DC to 500 MHz electrical probes (200V /1A max) - Prober material options such as tungsten-rhenium, beryllium-copper, or other materials - 25um or 5um tip radius options - Additional standalone electrical feedthroughs available by request |
Probe Positioning |
Manual cantilever probes independently positionable to any point of the sample area before sealing chamber. Standard probers Ideal for pad sizes larger than 600 um x 600 um. -MPeX sliding probers highly reccomended for pads between 250um x 250um* and 600um x 600um. *Smaller pad sizes require -MP or -MPS models |
Connectors |
Coaxial BNC connectors for HCP621G-MP base-model.
Floating, triaxial or SMA connectors available with HCP621G-MP+ model |
Sample Surface |
Electrically grounded sample area* (*Floating or triaxial options for back-biasing available with HCP621G-MP+ customizable model) |
Paramagnetic Components |
Contains Para-magnetic materials within 100mm of sample area. See HCP621G-PMH model for better Hall-effect compatability |
Optical Access |
Optical access to sample via reflection only * Transmission aperture may be available with HCP621G-MP+ customizable model |
Optical Windows |
Removable and exchangeable windows permit full-spectrum transparency. Window options include Soda-lime, quartz (default), CaF2, etc... |
Minimum Objective Working Distance |
8.5 mm |
Top Aperture |
-Ø28 mm with Ø31.75mm window |
Top Viewing Angle |
±50° (standard) |
Window Defrost |
External window defrost fixture |
Sample Area |
Ø26 mm (inscribed hexagon) (50mm x 50mm option available, contact us about the HCP602SG-MP) |
Chamber Height |
5 mm, max sample height of 2.5mm* *Optional spacer/ custom lid for increasing maximum sample height available with HCP621G-PM+ customizable model |
Sample Access |
Quick-access cover with spring-loaded screws.
Optional sample clips available for improved thermal contact, or for vertical mounting |
Atmosphere Control |
Supports +0.5 Bar Gas purging for controlling humidity, or reducing condensation or oxidation Note: For extended operation below -120ºC, evacuation is highly reccomended, as inert gas purge has limited effectivness in this temperature range |
Frame Cooling |
Integrated frame cooling with optional chiller system |
Mounting |
Horizontal or Vertical mounting capability. Base model includes tapped holes on frame and removable side-mounted L-Brackets. Horizontal mounting adaptors available for select instruments, or by custom design |
Frame Dimensions |
250 mm x 182 mm x 42 mm* *Overall device footprint may exceed these dimensions, be sure to consult a sales@instec.com to ensure fitment into optical instruments |
Weight |
2500g light-weight aluminum body |