High-temperature probing station
RT to 1000°C
Four electrical feedthroughs for electrical Probers
Vacuum-tight chamber for rough vacuum or inert gas purge
Top and Bottom frame water-cooling
This HP1000V-MP is a compact modular benchtop probing station with the ability to heat up to 1000°C. This probing station has modular components that can be customized for nearly any application. The base model includes a 1000°C heating core, capable of precision temperature control under vacuum for ambient conditions. Four independent electrical probers are manual controlled and upgradable to be controlled via micrometer dials for XYZ prober control - even when the chamber is sealed and under vacuum.
The Ø45mm viewing aperture on the chamber lid provides excellent optical access of the entire sample area, and is compatible with a wide range of optical analysis tools. The HP1000V-MP can even be mounted directly to an upright microscope to add temperature control, atmospheric control, and electrical probing capabilities into a single instrument.
Upgrade to the HP1000V-MP+ fully customizable model to add or remove probers, change electrical feedthrough types, add RF probers with rotational control, high cavuum capability, lerger sample areas, transmission aperture and more!
Note: the high-temperature thermal block radiates significant amounts of heat outwards from the optical window. Optics placed close to the optical window should be appropriately rated for the temperature and protected with water or air cooling.
Temperature Control |
mK2000 with programmable precision LVDC PID method to minimize electrical noise |
Thermal Block |
Silicon Carbide |
Temperature Minimum |
Ambient temperature, active cooling of the sample is not supported |
Temperature Maximum |
1000°C in vacuum, gas-purge, or ambient air environment |
Temperature Sensor |
S-type Thermocouple |
Temperature Resolution |
0.1°C (Thermocouple) |
Temperature Stability |
±0.1°C (>25°C) |
Software |
Windows software to record and export temperature-time data |
Optical Access |
Reflection (transmission option available) |
Optical Windows |
Removable and exchangeable windows permit full-spectrum transparency |
Minimum Objective Working Distance |
12mm |
Top Aperture |
Ø38mm, with Ø42mm window |
Top Viewing Angle |
±50° from normal |
Window Defrost |
External window defrost fixture |
Sample Area |
25mm x 25mm |
Chamber Height |
8mm |
Atmosphere Control |
Gas purging or vacuum capability to control humidity, condensation, and oxidation |
Frame Cooling |
Integrated frame cooling with water circulating system |
Frame Dimensions |
200mm x 200mm x 40mm |
Electrical Probes |
Standard tungsten-rhenium DC probes with other probe options available |
Probe Positioning |
Manual Positioning. Ideal for pad sizes larger than 250 um x 250 um* *Smaller pad sizes require -MPS models with micropositioner probers Upgradable to XYZ micro positioners to remotely manipulate probes within sealed sample chambers (10um resolution). |
Connectors |
Coaxial BNC connector (standard) *upgradable to triaxial BNC or SMA connectors |
Sample Surface |
Grounded (standard), floating, or triaxial options upon request |